Configuration choices
- Panel function
- Incoming, outgoing and bus-coupling circuits.
- Construction
- Fixed or withdrawable construction, cable entry and maintenance access.
- Protection information
- Circuit protection, metering and operating interlocks.
Distribution role • Construction • Protection information
Low-voltage switchgear distributes the main incoming supply to outgoing feeders and coordinates circuit protection, metering and operating controls.
Choose the arrangement below and add the details you have.

01 Technical data
Choose the arrangement below and add the details you have.
02 Application engineering
A main switchboard receives the transformer supply and feeds production lines, motor control centres and plant services. Busbar loading, prospective short-circuit current and coordination between incoming and outgoing protection determine the electrical arrangement. Feeder access and spare ways should support maintenance and planned expansion.
In offices, hotels and campuses, the main switchboard supplies risers, floor distribution boards and large mechanical loads. The load schedule defines feeder duties, metering and circuit allocation. Multiple supplies require a defined transfer and interlocking scheme; room dimensions, cable routes and maintenance clearances govern the physical layout.
New process equipment or additional building loads can require extra feeders or replacement of a main board. Existing drawings, fault levels, busbar interfaces and cable sizes must be checked before designing the extension. Available space, isolation arrangements and the agreed shutdown sequence shape how the new section connects.
03 Select your configuration
All fields are optional. Choose one or more options as indicated; use Other for a custom requirement.
Select one option.
Select all that apply.
Select one option.
Select all that apply.
Enter details
Enter details
Enter details
Enter details
Enter details
Enter details
Electrical values entered here are requested requirements. Equipment ratings must match the selected model and its technical datasheet.
04 Construction and options
05 Applicable standards and requirements

06 Manufacturing & Projects
Project Documents

Send existing drawings or lists. You can start an inquiry without a complete document package.
Ask for the following documents for the selected equipment. Document availability and delivery stage are agreed with the quotation.
07 Decision support

Send the following project information: System voltage, frequency, current and short-circuit duty with duration. Single-line diagram, feeder schedule and spare circuits.
A main switchboard handles the incoming supply and main feeders. A distribution board groups downstream circuits serving an area or specific loads.
State the prospective fault current, required withstand duration and protection arrangement. These requirements must be checked against the proposed model's documentation.
Let’s discuss your project
Send the following project information: System voltage, frequency, current and short-circuit duty with duration. Single-line diagram, feeder schedule and spare circuits. Installation space, cable routes and environmental conditions.
Alternative contact