Configuration choices
- Panel function
- Incoming, outgoing, metering and bus-coupling functions.
- Requested construction
- Fixed or withdrawable construction and cable access.
- Protection information
- Relays, CTs, VTs, earthing and interlocks.
Panel function • Requested construction • Protection information
Medium-voltage switchgear provides switching, isolation, metering and protection for incoming supplies and outgoing feeders.
Choose the arrangement below and add the details you have.

01 Technical data
Choose the arrangement below and add the details you have.
02 Application engineering
Medium-voltage incoming and transformer feeder panels provide switching, isolation and protection between the supply network and transformers. The single-line diagram defines the panel functions and busbar arrangement. System voltage, fault level, CT/VT requirements and relay coordination must be established together with cable access and maintenance space.
Plants with several transformer substations use medium-voltage feeders to distribute power across the site. A radial or ring arrangement needs a defined switching philosophy, interlocks and protection coordination. Cable characteristics, earthing arrangements and operating procedures guide panel selection; remote indication and control depend on the site's supervision requirements.
Campuses, transport facilities and large commercial developments use medium-voltage switchgear upstream of their low-voltage distribution. Transformer capacity and the required supply arrangement determine feeder functions and metering. Room access, cable termination space, ventilation and pressure-relief provisions must be assessed against the selected equipment and installation design.
03 Select your configuration
All fields are optional. Choose one or more options as indicated; use Other for a custom requirement.
Select one option.
Enter details
Select all that apply.
Select all that apply.
Enter details
Enter details
Enter details
Enter details
Enter details
Enter details
Electrical values entered here are requested requirements. Equipment ratings must match the selected model and its technical datasheet.
Confirm model ratings and installation limits from manufacturer documents.
04 Construction and options
05 Applicable standards and requirements

06 Manufacturing & Projects


Project Documents

Send existing drawings or lists. You can start an inquiry without a complete document package.
Ask for the following documents for the selected equipment. Document availability and delivery stage are agreed with the quotation.
07 Decision support

Send the following project information: System voltage, frequency, current and short-time withstand duty. Single-line diagram, protection study and instrument-transformer schedule.
Their switching, protection and operating functions can differ. Select the arrangement from the network diagram, protection duties and maintenance requirements.
Provide fault levels, protection coordination, relay functions, CT/VT data and earthing requirements for each circuit.