Rated capacity1P 15–250 kVA / 3P 10–1600 kVA
Primary voltage11 / 33 kV
PhasesSingle-phase / three-phase
ApplicationsUnderground distribution / Residential developments

Rated capacity: 1P 15–250 kVA / 3P 10–1600 kVA · Primary voltage: 11 / 33 kV · Secondary voltage: 400/230 V

Pad-Mounted Transformers

01 Technical data

Specifications for initial selection

Rated capacity: 1P 15–250 kVA / 3P 10–1600 kVA · Primary voltage: 11 / 33 kV · Secondary voltage: 400/230 V

Rated capacity
1P: 15 / 25 / 37.5 / 50 / 75 / 100 / 167 / 250 kVA; 3P: 10 / 15 / 20 / 25 / 30 / 50 / 63 / 80 / 100 / 125 / 160 / 200 / 250 / 315 / 400 / 500 / 630 / 800 / 1000 / 1250 / 1600 kVA
Primary voltage
11 / 33 kV
Secondary voltage
400/230 V
Phases
Single-phase / three-phase
Tap range
±2 × 2.5% / ±3 × 2.5% / ±5%
Vector group
Yyn0 / Dyn11
Feed type
Loop / radial / terminal feed
Short-circuit impedance
4.0% / 4.5%

02 Application engineering

Applications

Pad-mounted transformers for underground and compact surface distribution in Zambia (11 / 33 kV), combining protected MV/LV compartments with ground-level installation for residential, commercial and industrial developments including projects in mining, hydropower and industrial parks.

01

Underground distribution networks

Transformation at ground level in underground MV cable networks (11 / 33 kV), with protected compartments instead of a substation building. Suits cities and new developments where overhead lines are restricted and cable terminations must be enclosed.

02

Renewable and private distribution

Collector and auxiliary transformation for solar farms, wind sites and mine or plant private networks. Ground-level compartments simplify cable entry from underground collector circuits and can be configured to the owner protection scheme.

03

Industrial parks and private networks

Distribution within industrial estates, logistics sites and private MV networks (mining, hydropower and industrial parks), using loop, radial or terminal feed. Pad-mounted units can be added in stages as plots are occupied, without building a separate substation for each load.

Where to apply

  • Underground distribution
  • Renewable and private networks
  • Industrial parks
  • Residential developments
  • Commercial complexes
  • Campuses and institutions

03 Define your configuration

Configure your transformer

Select the main project parameters.

Rated capacity

Single-phase

three-phase

Primary voltage

Secondary voltage

Phases

Additional options

Tap range

Vector group

Short-circuit impedance

Feed type

04 Construction and options

Technical resources and options

Typical configuration

Lockable steel enclosure with separate high-voltage and low-voltage compartments and tamper-resistant access, installed at ground level beside the load.

Available option

Feed configuration: radial, loop or terminal feed, with the MV switching and bushing arrangement matched to the cable network layout and agreed per project.

Available option

MV connection and cable termination: separable connectors, bushing wells and inserts, or cable-box terminations suited to the specified cable type.

Available option

Fusing and switching: protective fuses, load-break switching and arrester provisions can be built in according to the network protection philosophy.

Available option

LV compartment: LV terminals or busbars, protected outgoing circuits and space for metering or auxiliary equipment according to the utility requirement and IEC 60076 and the ZESCO / CEC / project technical specification.

Project engineering

Plinth and cable entry: concrete or fabricated base with cable pit, oil containment and sealing against water and vermin ingress, dimensioned to the site layout. Environmental engineering for variable outdoor exposure such as UV, rain, wind and coastal or industrial atmosphere depending on the site: corrosion protection, ventilation, flood-risk placement and project-specific protection or monitoring are confirmed at project level.

05 Applicable standards and requirements

Standards & engineering

IEC / project feed, termination, enclosure, switching/fusing and mining/commercial requirements
IEC / project feed, termination, enclosure, switching/fusing and mining/commercial requirements.
ZESCO / project utility requirements
IEC / project feed, termination, enclosure, switching/fusing and mining/commercial requirements.
Primary voltage
11 / 33 kV
Secondary voltage
400/230 V
Request compliance and engineering documents

06 Manufacturing process

From production to testing

Production — Pad-Mounted Transformers
01Production
Assembly — Pad-Mounted Transformers
02Assembly
Testing — Pad-Mounted Transformers
03Testing

Downloads & support

Technical documents

HKXR POWER Technical Selection Guide

Guide for initial technical selection of distribution, power, dry-type, pole-mounted and pad-mounted transformers.

Unlock download

Complete your details to download the HKXR POWER Technical Selection Guide.

07 Decision support

Frequently asked questions

When should Pad-Mounted Transformers be selected instead of Pole-Mounted Transformers?

For Zambia, choose Pad-Mounted Transformers when the main duties are Underground distribution and Renewable and private networks; compare Pole-Mounted Transformers when Overhead distribution and Utility distribution feeders better match the site. Final selection depends on the installation environment, network topology, fire or oil-containment requirements, rating and project specification.

How should the main configuration options for Pad-Mounted Transformers be selected?

Key choices include radial / loop / terminal feed, MV cable connectors and switching and fusing. Select them according to the load profile, connection arrangement, installation environment, protection philosophy and utility/EPC specification; items shown as options or project engineering are not automatic standard equipment.

What installation conditions should be confirmed for Pad-Mounted Transformers projects in Zambia?

Confirm ambient temperature, altitude, humidity, dust or corrosion exposure, indoor/outdoor location, ventilation, access and maintenance clearances. For applications such as Underground distribution, Renewable and private networks and Industrial parks, cooling, enclosure or insulation and protection should be reviewed during engineering rather than assuming one environmental class for the whole country.

Which standards and utility/project requirements should be confirmed in Zambia?

Use IEC / project feed, termination, enclosure, switching/fusing and mining/commercial requirements as the starting technical reference. Requirements from ZESCO / project utility requirements should also be confirmed. Final losses, temperature rise, impedance, taps, accessories, tests and documentation must be checked against the applicable project specification; this page does not imply automatic approval by any authority.

What tests, drawings and documents should be agreed before the purchase order?

Confirm the applicable routine tests, general arrangement drawings, electrical datasheet, accessory list and inspection/test documents before manufacturing. Type or special tests, witnessing and additional reports should be specified when the project requires them. For Pad-Mounted Transformers, also confirm site-specific environmental and installation engineering.

What information does HKXR need to prepare a technical quotation?

Provide at least Rated capacity, Primary voltage, Secondary voltage, Phases, the selected radial / loop / terminal feed / MV cable connectors options, installation conditions and the applicable project or utility specification. If available, attach the SLD, datasheet or tender specification so the configuration can be reviewed before quotation.

Let’s discuss your project

Request a quote

Review your configuration and continue via WhatsApp.

Alternative contact

WhatsApp

Selected configuration

Select the main project parameters.

Edit configuration

Attach the technical data sheet, single-line diagram, photos or project documents. Send the file manually via WhatsApp.

Send by email

We use the details you submit to respond to this enquiry. Privacy.