Products
HKXR POWER

Distribution role • Mounting • Cable entry

Distribution Boards & SMDB

Distribution boards organise downstream circuits, protective devices and load connections for individual areas or equipment groups.

Distribution roleMain or sub-distribution, lighting and equipment supplies.
MountingWall-mounted / Floor-standing
Cable entryTop / Bottom / Side
Project informationLoad list

Choose the arrangement below and add the details you have.

Distribution Boards & SMDB

01 Technical data

Configuration & project information

Choose the arrangement below and add the details you have.

Configuration choices

Distribution role
Main or sub-distribution, lighting and equipment supplies.
Mounting
Wall or floor mounting, enclosure access and cable entries.
Panel function
Incoming protection, outgoing circuits, terminals and identification.

Information to provide

Supply voltage requested
System voltage, phases and circuit load schedule.
Protection information
Circuit currents, protection requirements and spare ways.
Installation
Available dimensions, mounting surface and installation environment. Include the owner specification, network requirements and actual temperature, dust and installation conditions.

02 Application engineering

Applications

01

Lighting and final circuits

Floor and area distribution boards divide the supply into lighting, socket and dedicated equipment circuits. A circuit schedule establishes load allocation, phase balance and spare ways. Protective devices, residual-current protection where required, neutral arrangements and clear circuit identification are selected for the connected loads and earthing system.

02

Local industrial distribution

Sub-distribution boards supply workshop equipment, maintenance outlets and auxiliary loads close to the point of use. Feeder and branch protection must coordinate with the upstream board and suit the local fault level. Load duty, cable entries and accessible isolation determine the circuit arrangement and enclosure dimensions.

03

Pump rooms and outdoor services

Boards for pumps, external lighting and service equipment need an enclosure suited to the installation location. Rain, dust, condensation and corrosion influence material, protection and cable-entry choices. Mounting position, maintenance access and the load schedule should be established before specifying the completed board.

03 Select your configuration

Select your configuration

All fields are optional. Choose one or more options as indicated; use Other for a custom requirement.

Distribution role

Select all that apply.

Mounting

Select one option.

Installation

Select one option.

Cable entry

Select all that apply.

Additional requirements

Supply voltage requested

Enter details

Current requirement (A)

Enter details

Enclosure requirement

Enter details

Component preference

Enter details

Supply frequency

Enter details

Current requirement (A)

Enter details

Electrical values entered here are requested requirements. Equipment ratings must match the selected model and its technical datasheet.

04 Construction and options

Technical options

Protection information

The incoming device must suit the supply and required isolation.

Panel function

Outgoing devices are selected for each load and circuit duty.

Mounting

Mounting and door access must match the installation location.

Metering

Meters and indicators are specified by the quantities and signals required.

Wiring diagram

Wire and terminal identifiers must correspond to the circuit drawings.

Cable entry

Cable entries and enclosure protection are defined for the installation environment.

05 Applicable standards and requirements

Standards

Distribution Boards & SMDB
Project specification
Technical references: IEC 61439-1 / IEC 61439-2 / IEC 61439-3. Confirm the applicable part and edition against the intended use and the proposed assembly documents. IEC 61439-3 applies to distribution boards intended for operation by ordinary persons within its scope; industrial assemblies require the appropriate product part.
Rating schedule
Confirm model ratings and installation limits from manufacturer documents.
Verification documents
Request verification and inspection records for the exact configuration.
Supply scope
Specify equipment, components, engineering, software and documents separately; the quotation confirms included items.
Request equipment documents

06 Manufacturing & Projects

Manufacturing & Projects

Manufacturing & Projects
01Manufacturing & Projects
Actual XL-21 cabinet door wiring, breakers and terminal strips
02Assembly & wiring
Applications
03Applications

Project Documents

Project Documents

Distribution Boards & SMDB

Documents you can send

Send existing drawings or lists. You can start an inquiry without a complete document package.

  • Load list
  • Wiring diagram
  • GA drawing
  • Enclosure and mounting drawing
Share project requirements

Documents to request

Ask for the following documents for the selected equipment. Document availability and delivery stage are agreed with the quotation.

  • Supply scope and component schedule
  • General arrangement and wiring diagrams
  • Model datasheets and verification records
Request equipment documents

07 Decision support

Frequently asked questions

Distribution Boards & SMDB
What information is needed for a quotation?

Send the following project information: System voltage, phases and circuit load schedule. Circuit currents, protection requirements and spare ways.

Is an empty enclosure the same as an assembled distribution board?

An enclosure provides mechanical housing. An assembled board also includes the devices, connections and identification specified for its circuits.

What should a circuit schedule contain?

List each load, circuit current, poles or phases, protective device and required spare circuits. Include mounting and cable-entry requirements.

Let’s discuss your project

Request a quote

Send the following project information: System voltage, phases and circuit load schedule. Circuit currents, protection requirements and spare ways. Available dimensions, mounting surface and installation environment.

Alternative contact

WhatsApp

Selected configuration

Choose the arrangement below and add the details you have.

Edit configuration

Files are not uploaded here. Attach the selected file in WhatsApp or your email application.

Send by email

Fields marked * are required for email only. Review the draft, add attachments and send it in your email app. WhatsApp needs no form fields.

We use the details you submit to respond to this enquiry. Privacy.